| Code |
Test Description
* Indicates send out test |
| T455 |
Free T3 |
 |
| Specimen |
1 ml serum |
| Method |
RIA |
| Schedule |
24 working days |
| Indication |
Evaluation of thyroid status in dogs. |
Interpretive Guidelines |
Levels may be low in dogs with hypothyroidism. Levels may be elevated slightly in euthyroid dogs
with increased tissue metabolic demands, and are typically spuriously high or very high in dogs with T3 autoantibodies. |
 |
| T460 |
Free T4 by Equilibrium Dialysis |
 |
| Specimen |
1 ml serum |
| Method |
Equilibrium Dialysis |
| Schedule |
24 working days |
| Indication |
This is the preferred assay for differentiation of sick euthyroid dogs from dogs with
hypothyroidism. This is the most sensitive test for diagnosing feline hyperthyroidism. |
Interpretive Guidelines |
Free T4 by dialysis is not affected by T4 autoantibodies. Free T4 by dialysis may be decreased in
some sick euthyroid dogs.
Cats: An elevated Free T4 by diasysis is consistent with hyperthyroidism, although a small percentage of euthyroid
cats with other illnesses can have an elevated free T4. |
 |
| S16345 |
Fructosamine |
 |
| Specimen |
1 ml serum, heparinized or EDTA plasma |
| Method |
Colorimetric |
| Schedule |
12 working days |
| Indication |
To differentiate diabetes mellitus from other causes of hyperglycemia and to assess glycemic
regulation in patients with diabetes. |
Interpretive Guidelines |
Elevated levels indicate uncontrolled or poorly controlled diabetes mellitus. |
| Comments |
Fructosamine concentrations must be interpreted in conjunction with clinical signs. |
 |
| T145 |
GGT |
 |
| Specimen |
1 ml serum |
| Method |
Kinetic |
| Schedule |
Daily |
| Indication |
Liver disease |
Interpretive Guidelines |
Elevation may be due to intra or post-hepatic cholestasis or corticosteroid administration. |
 |
| T820 |
Giardia Antigen |
 |
| Specimen |
2 g fresh feces |
| Method |
ELISA |
| Schedule |
12 working days |
| Indication |
Evaluation of patients with vomiting and/or diarrhea. |
| Comments |
This test may be more sensitive than the zinc sulfate centrifugation/flotation test or direct IFA. |
 |
| T150 |
Glucose |
 |
| Specimen |
1 ml serum or heparinized plasma (separated) |
| Method |
Hexokinase |
| Schedule |
Daily |
| Indication |
High levels associated with diabetes or stress. Low levels associated with seizures. |
Interpretive Guidelines |
High levels associated with diabetes and stress hyperglycemia. Low levels may be artifactual or
associated with insulin overdose, insulinoma, hepatic failure, pregnancy toxemia, sepsis, Addison's disease or
toy-breed hypoglycemia. |
| Comments |
Whole blood in red top tube may decrease results due to utilization of glucose by blood cells. |
 |
 |
 |
|
|
 |
Please send comments to the webmaster.
©1997-2008 Antech Diagnostics, Inc.